[Docs] [txt|pdf] [draft-ietf-ccam...] [Tracker] [Diff1] [Diff2]
Updated by: 6898 PROPOSED STANDARD
Network Working Group A. Fredette, Ed.
Request for Comments: 4209 Hatteras Networks
Category: Standards Track J. Lang, Ed.
Sonos Inc.
October 2005
Link Management Protocol (LMP) for
Dense Wavelength Division Multiplexing (DWDM) Optical Line Systems
Status of This Memo
This document specifies an Internet standards track protocol for the
Internet community, and requests discussion and suggestions for
improvements. Please refer to the current edition of the "Internet
Official Protocol Standards" (STD 1) for the standardization state
and status of this protocol. Distribution of this memo is unlimited.
Copyright Notice
Copyright (C) The Internet Society (2005).
Abstract
The Link Management Protocol (LMP) is defined to manage traffic
engineering (TE) links. In its present form, LMP focuses on peer
nodes, i.e., nodes that peer in signaling and/or routing. This
document proposes extensions to LMP to allow it to be used between a
peer node and an adjacent optical line system (OLS). These
extensions are intended to satisfy the "Optical Link Interface
Requirements" described in a companion document.
1. Introduction
Networks are being developed with routers, switches, optical cross-
connects (OXCs), dense wavelength division multiplexing (DWDM)
optical line systems (OLSes), and add-drop multiplexors (ADMs) that
use a common control plane (e.g., Generalized MPLS (GMPLS)) to
dynamically provision resources and to provide network survivability
using protection and restoration techniques.
The Link Management Protocol (LMP) is being developed as part of the
GMPLS protocol suite to manage traffic engineering (TE) links
[RFC4204]. In its present form, LMP focuses on peer nodes, i.e.,
nodes that peer in signaling and/or routing (e.g., OXC-to-OXC, as
illustrated in Figure 1). In this document, extensions to LMP are
proposed to allow it to be used between a peer node and an adjacent
optical line system (OLS). These extensions are intended to satisfy
Fredette & Lang Standards Track [Page 1]
RFC 4209 LMP for DWDM Optical Line Systems October 2005
the "Optical Link Interface Requirements" described in [OLI]. It is
assumed that the reader is familiar with LMP, as defined in
[RFC4204].
+------+ +------+ +------+ +------+
| | ----- | | | | ----- | |
| OXC1 | ----- | OLS1 | ===== | OLS2 | ----- | OXC2 |
| | ----- | | | | ----- | |
+------+ +------+ +------+ +------+
^ ^
| |
+---------------------LMP---------------------+
Figure 1: LMP Model
Consider two peer nodes (e.g., two OXCs) interconnected by a
wavelength-multiplexed link, i.e., a DWDM optical link (see Figure 1
above). Information about the configuration of this link and its
current state is known by the two OLSes (OLS1 and OLS2). Allowing
them to communicate this information to the corresponding peer nodes
(OXC1 and OXC2) via LMP can improve network usability by reducing
required manual configuration and by enhancing fault detection and
recovery.
Information about the state of LSPs using the DWDM optical link is
known by the peer nodes (OXC1 and OXC2), and allowing them to
communicate this information to the corresponding OLSes (OLS1 and
OLS2) is useful for alarm management and link monitoring. Alarm
management is important because the administrative state of an LSP,
known to the peer nodes (e.g., via the Admin Status object of GMPLS
signaling [RFC3471]), can be used to suppress spurious alarm
reporting from the OLSes.
The model for extending LMP to OLSes is shown in Figure 2.
+------+ +------+ +------+ +------+
| | ----- | | | | ----- | |
| OXC1 | ----- | OLS1 | ===== | OLS2 | ----- | OXC2 |
| | ----- | | | | ----- | |
+------+ +------+ +------+ +------+
^ ^ ^ ^ ^ ^
| | | | | |
| +-----LMP-----+ +-----LMP-----+ |
| |
+----------------------LMP-----------------------+
Figure 2: Extended LMP Model
Fredette & Lang Standards Track [Page 2]
RFC 4209 LMP for DWDM Optical Line Systems October 2005
In this model, a peer node may have LMP sessions with adjacent OLSes,
as well as adjacent peer nodes. In Figure 2, for example, the OXC1-
OXC2 LMP session can be used to build traffic-engineering (TE) links
for GMPLS signaling and routing, as described in [RFC4204]. The
OXC1-OLS1 and the OXC2-OLS2 LMP sessions are used to exchange
information about the configuration of the DWDM optical link and its
current state and information about the state of LSPs using that
link.
The latter type of LMP sessions is discussed in this document. It is
important to note that a peer node may have LMP sessions with one or
more OLSes and an OLS may have LMP sessions with one or more peer
nodes.
Although there are many similarities between an LMP session between
two peer nodes and an LMP session between a peer node and an OLS,
there are some differences as well. The former type of LMP session
is used to provide the basis for GMPLS signaling and routing. The
latter type of LMP session is used to augment knowledge about the
links between peer nodes.
A peer node maintains its peer node-to-OLS LMP sessions and its peer
node-to-peer node LMP sessions independently. This means that it
MUST be possible for LMP sessions to come up in any order. In
particular, it MUST be possible for a peer node-to-peer node LMP
session to come up in the absence of any peer node-to-OLS LMP
sessions, and vice versa.
1.1. Terminology
The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT",
"SHOULD", "SHOULD NOT", "RECOMMENDED", "MAY", and "OPTIONAL" in this
document are to be interpreted as described in [RFC2119].
The reader is assumed to be familiar with the terminology in
[RFC4204].
DWDM: Dense wavelength division multiplexing
OLS: Optical line system
Opaque:
A device is called X-opaque if it examines or modifies the X
aspect of the signal while forwarding an incoming signal from
input to output.
OXC: Optical cross-connect
Fredette & Lang Standards Track [Page 3]
RFC 4209 LMP for DWDM Optical Line Systems October 2005
Transparent:
As defined in [RFC4204], a device is called X-transparent if it
forwards incoming signals from input to output without examining
or modifying the X aspect of the signal. For example, a Frame
Relay switch is network-layer transparent; an all-optical switch
is electrically transparent.
1.2. Scope of LMP-WDM Protocol
This document focuses on extensions required for use with opaque
OLSes. In particular, this document is intended for use with OLSes
having SONET, SDH, and Ethernet user ports.
At the time of this writing, work is ongoing in the area of fully
transparent wavelength routing; however, it is premature to identify
the necessary information to be exchanged between a peer node and an
OLS in this context. Nevertheless, the protocol described in this
document provides the necessary framework in which to exchange
additional information that is deemed appropriate.
2. LMP Extensions for Optical Line Systems
LMP currently consists of four main procedures, of which the first
two are mandatory and the last two are optional:
1. Control channel management
2. Link property correlation
3. Link verification
4. Fault management
All four functions are supported in LMP-WDM.
2.1. Control Channel Management
As in [RFC4204], we do not specify the exact implementation of the
control channel; it could be, for example, a separate wavelength,
fiber, Ethernet link, an IP tunnel routed over a separate management
network, a multi-hop IP network, or the overhead bytes of a data
link.
The control channel management for a peer node-to-OLS link is the
same as for a peer node-to-peer node link, as described in [RFC4204].
To distinguish between a peer node-to-OLS LMP session and a peer
node-to-peer node LMP session, a new LMP-WDM CONFIG object is defined
(C-Type = 2). The format of the CONFIG object is as follows:
Fredette & Lang Standards Track [Page 4]
RFC 4209 LMP for DWDM Optical Line Systems October 2005
Class = 6
o C-Type = 2, LMP-WDM_CONFIG
0 1 2 3
0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
|W|O| (Reserved) |
+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
The Reserved field should be sent as zero and ignored on receipt.
WDM: 1 bit
This bit indicates support for the LMP-WDM extensions defined
in this document.
OLS: 1 bit
If set, this bit indicates that the sender is an optical line
system (OLS). If clear, this bit indicates that the sender is
a peer node.
The LMP-WDM extensions are designed for peer node-to-OLS LMP
sessions. The OLS bit allows a node to identify itself as an OLS or
a peer node. This is used to detect misconfiguration of a peer
node-to-OLS LMP session between two peer nodes or a peer node-to-peer
node LMP session between a peer node and an OLS.
If the node does not support the LMP-WDM extensions, it MUST reply to
the Config message with a ConfigNack message.
If a peer node that is configured to run LMP-WDM receives a Config
message with the OLS bit clear in LMP-WDM_CONFIG object, it MUST
reply to the Config message with a ConfigNack message.
2.2. Link Verification
The Test procedure used with OLSes is the same as described in
[RFC4204]. The VerifyTransportMechanism (included in the BeginVerify
and BeginVerifyAck messages) is used to allow nodes to negotiate a
link verification method and is essential for line systems that have
access to overhead bytes rather than the payload. The VerifyId
(provided by the remote node in the BeginVerifyAck message and used
in all subsequent Test messages) is used to differentiate Test
messages from different LMP Link Verification procedures. In
Fredette & Lang Standards Track [Page 5]
RFC 4209 LMP for DWDM Optical Line Systems October 2005
addition to the Test procedure described in [RFC4204], the trace
monitoring function of [RFC4207] may be used for link verification
when the OLS user ports are SONET or SDH.
In a combined LMP and LMP-WDM context, there is an interplay between
the data links being managed by peer node-to-peer node LMP sessions
and peer node-to-OLS LMP sessions. For example, in Figure 2, the
OXC1-OLS1 LMP session manages the data links between OXC1 and OLS1,
and the OXC2-OLS2 LMP session manages the data links between OXC2 and
OLS2. However, the OXC1-OXC2 LMP session manages the data links
between OXC1 and OXC2, which are actually a concatenation of the data
links between OXC1 and OLS1, the DWDM span between OLS1 and OLS2, and
the data links between OXC2 and OLS2. It is these concatenated links
that comprise the TE links that are advertised in the GMPLS TE link
state database.
The implication of this is that when the data links between OXC1 and
OXC2 are being verified, using the LMP link verification procedure,
OLS1 and OLS2 need to make themselves transparent with respect to
these concatenated data links. The coordination of verification of
OXC1-OLS1 and OXC2-OLS2 data links to ensure this transparency is the
responsibility of the peer nodes, OXC1 and OXC2.
It is also necessary for these peer nodes to understand the mappings
between the data links of the peer node - OLS LMP session and the
concatenated data links of the peer node - peer node LMP session.
2.3. Link Summarization
As in [RFC4204], the LinkSummary message is used to synchronize the
Interface_Ids and correlate the properties of the TE link. (Note
that the term "TE link" originated from routing/signaling
applications of LMP, and this concept does not necessarily apply to
an OLS. However, the term is used in this document to remain
consistent with LMP terminology.) The LinkSummary message includes
one or more DATA_LINK objects. The contents of the DATA_LINK object
consist of a series of variable-length data items called Data Link
sub-objects describing the capabilities of the data links.
In this document, several additional Data Link sub-objects are
defined to describe additional link characteristics. The link
characteristics are, in general, those needed by the CSPF to select
the path for a particular LSP. These link characteristics describe
the specified peer node-to-OLS data link, as well as the associated
DWDM span between the two OLSes.
Fredette & Lang Standards Track [Page 6]
RFC 4209 LMP for DWDM Optical Line Systems October 2005
The format of the Data Link sub-objects follows the format described
in [RFC4204] and is shown below for readability:
0 1
0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5
+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+---------------//--------------+
| Type | Length | (Sub-object contents) |
+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+---------------//--------------+
Type: 8 bits
The Type indicates the type of contents of the sub-object.
Length: 8 bits
The Length field contains the total length of the sub-object in
bytes, including the Type and Length fields. The Length MUST
be at least 4, and MUST be a multiple of 4.
The following link characteristics are exchanged on a per data link
basis.
2.3.1. Link Group ID
The main purpose of the Link Group ID is to reduce control traffic
during failures that affect many data links. A local ID may be
assigned to a group of data links. This ID can be used to reduce the
control traffic in the event of a failure by enabling a single
ChannelStatus message with the LINK GROUP CHANNEL_STATUS object (see
Section 2.4.1) to be used for a group of data links instead of
individual ChannelStatus messages for each data link. A data link
may be a member of multiple groups. This is achieved by including
multiple Link Group ID sub-objects in the LinkSummary message.
The Link Group ID feature allows Link Groups to be assigned based on
the types of fault correlation and aggregation supported by a given
OLS. From a practical perspective, the Link Group ID is used to map
(or group) data links into "failable entities" known primarily to the
OLS. If one of those failable entities fails, all associated data
links are failed and the peer node is notified with a single message.
For example, an OLS could create a Link Group for each laser in the
OLS. The data links associated with each laser would then each be
assigned the Link Group ID for that laser. If a laser fails, the OLS
would then report a single failure affecting all of the data links
with a Link Group ID of the failed laser. The peer node that
receives the single failure notification then knows which data links
are affected. Similarly, an OLS could create a Link Group ID for a
Fredette & Lang Standards Track [Page 7]
RFC 4209 LMP for DWDM Optical Line Systems October 2005
fiber, to report a failure affecting all of the data links associated
with that fiber if a loss-of-signal (LOS) is detected for that fiber.
The format of the Link Group ID sub-object (Type = 3, Length = 8) is
as follows:
0 1 2 3
0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
| Type | Length | (Reserved) |
+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
| Link Group ID |
+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
The Reserved field should be sent as zero and ignored on receipt.
Link Group ID: 32 bits
Link Group ID 0xFFFFFFFF is reserved and indicates all data
links in a TE link. All data links are members of Link Group
0xFFFFFFFF by default.
2.3.2. Shared Risk Link Group (SRLG) Identifier
This identifies the SRLGs of which the data link is a member. This
information may be configured on an OLS by the user and used for
diverse path computation (see [RFC4202]).
The format of the SRLG sub-object (Type = 4, Length = (N+1)*4 where N
is the number of SRLG values) is as follows:
0 1 2 3
0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
| Type | Length | (Reserved) |
+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
| SRLG value #1 |
+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
| SRLG value #2 |
+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
// ... //
+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
| SRLG value #(N-1) |
+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
| SRLG value #N |
+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
The Reserved field should be sent as zero and ignored on receipt.
Fredette & Lang Standards Track [Page 8]
RFC 4209 LMP for DWDM Optical Line Systems October 2005
Shared Risk Link Group Value: 32 bits
See [RFC4202]. List as many SRLGs as apply.
2.3.3. Bit Error Rate (BER) Estimate
This object provides an estimate of the BER for the data link.
The Bit Error Rate (BER) is the proportion of bits that have errors
relative to the total number of bits received in a transmission,
usually expressed as ten to a negative power. For example, a
transmission might have a BER of "10 to the minus 13", meaning that,
out of every 10,000,000,000,000 bits transmitted, one bit may be in
error. The BER is an indication of overall signal quality.
The format of the BER Estimate sub-object (Type = 5; Length = 4) is
as follows:
0 1 2 3
0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
| Type | Length | BER | (Reserved) |
+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
The Reserved field should be sent as zero and ignored on receipt.
BER: 8 bits
The exponent from the BER representation described above. That
is, if the BER is 10 to the minus X, the BER field is set to X.
2.3.4. Optical Protection
This indicates whether the link is protected by the OLS. This
information can be used as a measure of link capability. It may be
advertised by routing and used by signaling as a selection criterion,
as described in [RFC3471].
The format of the Optical Protection sub-object (Type = 6; Length =
4) is as follows:
0 1 2 3
0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
| Type | Length | (Reserved) | Link Flags|
+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
The Reserved field should be sent as zero and ignored on receipt.
Fredette & Lang Standards Track [Page 9]
RFC 4209 LMP for DWDM Optical Line Systems October 2005
Link Flags: 6 bits
Encoding for Link Flags is defined in Section 7 of [RFC3471].
2.3.5. Total Span Length
This indicates the total distance of fiber in the OLS. This may be
used as a routing metric or to estimate delay.
The format of the Total Span Length sub-object (Type = 7, Length = 8)
is as follows:
0 1 2 3
0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
| Type | Length | (Reserved) |
+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
| Span Length |
+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
The Reserved field should be sent as zero and ignored on receipt.
Span Length: 32 bits
This value represents the total length of the WDM span in
meters, expressed as an unsigned (long) integer.
2.3.6. Administrative Group (Color)
The administrative group (or Color) to which the data link belongs.
The format of the Administrative Group sub-object (Type = 8, Length =
8) is as follows:
0 1 2 3
0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
| Type | Length | (Reserved) |
+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
| Administrative Group |
+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
The Reserved field should be sent as zero and ignored on receipt.
Administrative Group: 32 bits
A 32-bit value, as defined in [RFC3630].
Fredette & Lang Standards Track [Page 10]
RFC 4209 LMP for DWDM Optical Line Systems October 2005
2.4. Fault Management
The Fault Management procedure used between a peer and an OLS follows
the procedures described in [RFC4204]; some further extensions are
defined in this section. The information learned from the OLS-peer
fault management procedures may be used to trigger peer-peer LMP
fault management, or may be used to trigger GMPLS signaling/routing
procedures directly.
Fault management consists of three major functions:
1. Fault Detection
2. Fault Localization
3. Fault Notification
The fault detection mechanisms are the responsibility of the
individual nodes and are not specified as part of this protocol.
Fault detection mechanisms may include a Bit Error Rate (BER)
exceeding a threshold, and loss-of-signal (LOS) and SONET/SDH-level
errors. It is the responsibility of the OLS to translate these
failures into (Signal) OK, Signal Failure (SF), or Signal Degrade
(SD), as described in [RFC4204].
That is, an OLS uses the messages defined in the LMP fault
localization procedures (ChannelStatus, ChannelStatusAck,
ChannelStatusRequest, and ChannelStatusResponse messages) to inform
the adjacent peer node of failures it has detected, in order to
initiate the LMP fault localization procedures between peer nodes,
but it does not participate in those procedures.
The OLS may also execute its own fault localization process to allow
it to determine the location of the fault along the DWDM span. For
example, the OLS may be able to pinpoint the fault to a particular
amplifier in a span of thousands of kilometers in length.
To report data link failures and recovery conditions, LMP-WDM uses
the ChannelStatus, ChannelStatusAck, ChannelStatusRequest, and
ChannelStatusResponse messages defined in [RFC4204].
Each data link is identified by an Interface_ID. In addition, a Link
Group ID may be assigned to a group of data links (see Section
2.3.1). The Link Group ID may be used to reduce the control traffic
by providing channel status information for a group of data links. A
new LINK GROUP CHANNEL_STATUS object is defined below for this
purpose. This object may be used in place of the CHANNEL_STATUS
objects described in [RFC4204] in the ChannelStatus message.
Fredette & Lang Standards Track [Page 11]
RFC 4209 LMP for DWDM Optical Line Systems October 2005
2.4.1. LINK_GROUP CHANNEL_STATUS Object
The LINK_GROUP CHANNEL_STATUS object is used to indicate the status
of the data links belonging to a particular Link Group. The
correlation of data links to Group ID is made with the Link Group ID
sub-object of the DATA_LINK object.
The format of the LINK_GROUP CHANNEL_STATUS object is as follows
(Class = 13, C-Type = 4):
0 1 2 3
0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
| Link Group ID |
+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
|A|D| Channel Status |
+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
| : |
// : //
| : |
+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
| Link Group ID |
+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
|A|D| Channel Status |
+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
Link Group ID: 32 bits
The Link Group ID 0xFFFFFFFF is reserved and indicates all data
links in a TE link. All data links are members of the Link
Group 0xFFFFFFFF by default.
Channel Status: 32 bits
The values for the Channel Status field are defined in
[RFC4204].
This object is non-negotiable.
3. Security Considerations
LMP message security uses IPsec, as described in [RFC4204]. This
document only defines new LMP objects that are carried in existing
LMP messages. As such, this document introduces no other new
security considerations not covered in [RFC4204].
Fredette & Lang Standards Track [Page 12]
RFC 4209 LMP for DWDM Optical Line Systems October 2005
4. IANA Considerations
LMP [RFC4204] defines the following name spaces and the ways in which
IANA can make assignments to these namespaces:
- LMP Message Type
- LMP Object Class
- LMP Object Class type (C-Type) unique within the Object Class
- LMP Sub-object Class type (Type) unique within the Object Class
This memo introduces the following new assignments:
LMP Object Class Types:
o under CONFIG class name (as defined in [RFC4204])
- LMP-WDM_CONFIG (C-Type = 2)
o under CHANNEL_STATUS class name (as defined in [RFC4204])
- LINK_GROUP (C-Type = 4)
LMP Sub-Object Class names:
o under DATA_LINK Class name (as defined in [RFC4204])
- Link_GroupId (sub-object Type = 3)
- SRLG (sub-object Type = 4)
- BER_Estimate (sub-object Type = 5)
- Optical_Protection (sub-object Type = 6)
- Total_Span_Length (sub-object Type = 7)
- Administrative_Group (sub-object Type = 8)
5. Contributors
The authors would like to acknowledge Osama S. Aboul-Magd, Stuart
Brorson, Sudheer Dharanikota, John Drake, David Drysdale, W. L.
Edwards, Adrian Farrel, Andre Fredette, Rohit Goyal, Hirokazu
Ishimatsu, Monika Jaeger, Ram Krishnan, Jonathan P. Lang, Raghu
Mannam, Eric Mannie, Dimitri Papadimitriou, Jagan Shantigram, Ed
Snyder, George Swallow, Gopala Tumuluri, Yong Xue, Lucy Yong, and
John Yu.
Fredette & Lang Standards Track [Page 13]
RFC 4209 LMP for DWDM Optical Line Systems October 2005
6. References
6.1. Normative References
[RFC4202] Kompella, K., Ed., and Y. Rekhter, Ed., "Routing
Extensions in Support of Generalized Multi-Protocol Label
Switching (GMPLS)", RFC 4202, September 2005.
[RFC4204] Lang, J., Ed., "The Link Management Protocol (LMP)", RFC
4204, September 2005.
[RFC4207] Lang, J., and D. Papadimitriou, "Synchronous Optical
Network (SONET)/Synchronous Digital Hierarchy (SDH)
Encoding for Link Management Protocol (LMP) Test
Messages", RFC 4207, September 2005.
[RFC2119] Bradner, S., "Key words for use in RFCs to Indicate
Requirement Levels", BCP 14, RFC 2119, March 1997.
[RFC3471] Berger, L., "Generalized Multi-Protocol Label Switching
(GMPLS) Signaling Functional Description", RFC 3471,
January 2003.
[RFC3630] Katz, D., Kompella, K., and D. Yeung, "Traffic
Engineering (TE) Extensions to OSPF Version 2", RFC 3630,
September 2003.
6.2. Informative References
[OLI] Fredette, A., Editor, "Optical Link Interface
Requirements", Work in Progress.
Fredette & Lang Standards Track [Page 14]
RFC 4209 LMP for DWDM Optical Line Systems October 2005
Editors' Addresses
Andre Fredette
Hatteras Networks
P.O. Box 110025
Research Triangle Park
NC 27709-0025, USA
EMail: Afredette@HatterasNetworks.com
Jonathan P. Lang
Sonos, Inc.
223 E. De La Guerra St.
Santa Barbara, CA 93101
EMail: jplang@ieee.org
Fredette & Lang Standards Track [Page 15]
RFC 4209 LMP for DWDM Optical Line Systems October 2005
Full Copyright Statement
Copyright (C) The Internet Society (2005).
This document is subject to the rights, licenses and restrictions
contained in BCP 78, and except as set forth therein, the authors
retain all their rights.
This document and the information contained herein are provided on an
"AS IS" basis and THE CONTRIBUTOR, THE ORGANIZATION HE/SHE REPRESENTS
OR IS SPONSORED BY (IF ANY), THE INTERNET SOCIETY AND THE INTERNET
ENGINEERING TASK FORCE DISCLAIM ALL WARRANTIES, EXPRESS OR IMPLIED,
INCLUDING BUT NOT LIMITED TO ANY WARRANTY THAT THE USE OF THE
INFORMATION HEREIN WILL NOT INFRINGE ANY RIGHTS OR ANY IMPLIED
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
Intellectual Property
The IETF takes no position regarding the validity or scope of any
Intellectual Property Rights or other rights that might be claimed to
pertain to the implementation or use of the technology described in
this document or the extent to which any license under such rights
might or might not be available; nor does it represent that it has
made any independent effort to identify any such rights. Information
on the procedures with respect to rights in RFC documents can be
found in BCP 78 and BCP 79.
Copies of IPR disclosures made to the IETF Secretariat and any
assurances of licenses to be made available, or the result of an
attempt made to obtain a general license or permission for the use of
such proprietary rights by implementers or users of this
specification can be obtained from the IETF on-line IPR repository at
http://www.ietf.org/ipr.
The IETF invites any interested party to bring to its attention any
copyrights, patents or patent applications, or other proprietary
rights that may cover technology that may be required to implement
this standard. Please address the information to the IETF at ietf-
ipr@ietf.org.
Acknowledgement
Funding for the RFC Editor function is currently provided by the
Internet Society.
Fredette & Lang Standards Track [Page 16]
Html markup produced by rfcmarkup 1.129b, available from
https://tools.ietf.org/tools/rfcmarkup/